Mac 5500 Ecg User Manualeagleecho



Mac 5500 HD ECG Systems by GE Healthcare Manufacturer: Ge Healthcare Premier ECG system designed to deliver advanced disease management capabilities through industry-leading collection of algorithms and advanced networking. System Overview The MAC 5500/MAC 5500 HD resting ECG analysis system is a 15-lead, 12-channel system with a 10.4 inch (264 mm) diagonal display, active patient cable, battery operation, and late potential electrocardiography. Advanced Electrocardiography Built on GE innovation in ECG acquisition and analysis, the MAC 5500 HD Resting ECG System is a premier ECG system, delivering advanced disease management capabilities through one of the industry-leading collections of algorithms and advanced networking. The GE Marquette. 12SL. ECG analysis program gives you the power of proven algorithms including ACI-TIPI and gender-specific interpretation. Our recent additions in the MAC. 5500 HD include high-definition pacemaker detection, ACS analysis, and user definable, critical values. View and Download GE HEALTHCARE MAC 5500 operator's manual online. Resting ECG Analysis System. MAC 5500 analytical instruments pdf manual download. Also for: Mac 5500 hd.

GE MAC 5500 HD EKG Machine

The GE MAC 5500 HD Resting ECG System is a premier ECG machine that delivers advanced disease management capabilities through one of the industry-leading collections of algorithms and advanced networking. The MAC 5500 HD precisely captures, analyzes, and communicates ECG data. Sophisticated tools built on an easy-to-use design and platform enables clinicians to focus on what’s most important: their patients.

Description

Mac 5500 Ecg Machine

GE MAC 5500 HD EKG Machine

The GE MAC 5500 HD EKG Machine is a premier ECG machine that delivers advanced disease management capabilities through one of the industry-leading collections of algorithms and advanced networking.

  • Better triaging tools for Acute Coronary Syndrome (ACS) detection.
  • Configurable Critical Values to help speed time to treatment.
  • More accurate pacemaker detection for advanced interpretation of paced rhythms.
  • Enhanced barcode workflow, with orders andADT download capability, work together to help improve efficiency across the enterprise.
  • Connected ECG Workflow to help save time and avoid costly misdiagnoses.
  • Advanced algorithms in ECG analysis and interpretation.
5500

GE MAC 2000 EKG Machine Specifications

Dimensions and Weight (Console)

  • Height: 3.7” (9.4 cm) (With display closed)
  • Width: 15” (38.1 cm)
  • Depth: 13.8” (35.1 cm)
  • Weight: 15 lbs (6.8 kg)

Dimensions and Weight (Cart)

  • Height: 37” (94 cm)
  • Width: 19” (47 cm)
  • Depth: 27” (69 cm)
  • Weight: 66 lbs (30 kg)

Display

  • Type: 10.4 in (264 mm) diagonal graphics backlit color AM LCD
  • Display Resolution: 640 x 480 pixels with waveform enhancement
  • Display Data: Heart rate, patient name, ID, clock, waveforms, lead labels, speed, gain and filter settings, warning messages, prompts, and help messages

Keyboard

  • Type: Sealed elastomer with soft function keys, alphanumeric keys, writer controls, and TrimPad cursor controls

Power

  • Power Supply: AC or battery operation
  • Voltage: 100 to 240 VAC
  • Current: 0.5A @ 115 VAC, 0.3A @ 240 VAC, typical, 0.85A max
  • Frequency: 50 to 60 Hz
  • Battery Type: User replaceable, 18V @ 3.5 AH ±10% rechargeable NiMH
  • Battery Capacity: 100 single-page reports, (typical) or six hours continuous display (without printing)
  • Battery Charge Time: Approximately 4.5 hours from total discharge (with the display off)

Environmental Operating Conditions

  • Temperature Range: 50°to 104° F (10° to 40° C)
  • Relative Humidity: 20% to 95% RH non-condensing
  • Atmospheric Pressure: 5700 to 1060 hPa

Environmental Storage Conditions

Mac 5500 Ecg Machine Manual

Mac
  • Temperature Range: –40°to 158° F (–40° to 70° C)
  • Relative Humidity: 15% to 95% RH non-condensing
  • Atmospheric Pressure: 500 to 1060 hPa
Mac 5500 ecg service manual

Magnetic Card Reader

  • Character Set: ANSI/ISO ALPHA alphanumeric characters and ANSI/ISO BCD (a subset of ASCII [ISO 646 IRV:1991])

Bar Code Scanner

  • Symbologies: Code 39 (extended), PDF-417, Code 128, Data Matrix, Interleaved 2 of 5

Processing

  • ECG Interpretation: Marquette* 12SL* ECG Analysis Program for Adults and Pediatrics
  • Computerized Measurements: 15-lead analysis includes measurements of user-selectable additional 3 leads
  • Optional: Hi-Res Late Potential Analysis and P-Wave Signal – Averaged ECG
  • Additional ECG Function: Vectorcardiography
  • ECG Analysis Frequency: 500 samples/second (sps)
  • ECG Storage: 200 ECGs in the internal memory
  • External Archiving: Secure Digital card
  • Digital Sampling Rate: 16,000 samples/second/channel
  • Pre-Acquisition: Provides 10 seconds of instantaneous ECG acquisition
  • Dynamic Range: AC Differential ± 5mV, DC offset ±300 mV
  • Resolution: 4.88 μV/LSB @ 250 sps, 4.88 μV/LSB @ 500 sps
  • Frequency Response: –3 dB @ 0.01 to 150 Hz
  • Common Mode Rejection: >140 dB (123 dB with AC filter disabled)
  • Input Impedance: >10MΩ @ 10 Hz, defibrillator protected
  • Patient Leakage:<10 μA
  • Pace Detection: Meets or exceeds ANSI/AAMI EC11-1991 standards
  • Pace Digital Sampling Rate: 75,000 samples / second / channel
  • Pace Pulse Width: as low as 0.2 ms in duration
  • Pace Pulse Amplitude: as low as 0.5 mV in amplitude
  • Special Acquisition Functions: Disconnected lead detection, electrode impedance, excessive AC noise, baseline wander, and muscle tremor messages
  • Heart Rate Meter: 30 to 300 BPM ±10% or 5 BPM, whichever is greater. Heart rates outside this range will not be displayed

Mac 5500 Manual

Writer

Mac
  • Writer Technology: Thermal dot array
  • Writer Speeds: 5, 12.5, 25, and 50 mm/s
  • Number of Traces: 3, 6, 12, or 15 user selectable
  • Writer Sensitivity/Gain: 2.5, 5, 10, 20, 10/5 (split calibration) mm/mV
  • Writer Resolution: Horizontal 1000 dpi @ 25 mm/s, 200 dpi vertical
  • Paper Type: Thermal, Z-fold, perforated, fan fold, 300 sheets/pack
  • Paper Size: A Size: 8.5 in x 11 in, (214.6 mm x 280 mm)
  • A4 Size: 8.27 in x 11.7 in (210 mm x 297.5 mm)

Related products

  • Philips PageWriter Touch EKG Machine

  • Welch Allyn Schiller AT 2 Plus EKG Machine

  • GE Marquette Mac 5000 EKG Machine

  • Philips PageWriter TC70 EKG Machine

GE-MAC 5500 ECG ANALYSIS SYSTEM EKG PATIENT MONITOR INCLUDED
SOLD AS-IS / UNTESTED, Unit Is In Good Cosmetic Condition, Minor Wear and Tear
Powers on.
Screen is clear.
Keyboard/buttons are all in PERFECT working.
The MAC 5500 HD represents a new definition of ECG speed and accuracy, and offers:
Better triaging tools for Acute Coronary Syndrome (ACS) detection
Configurable Crtical Values to help speed time to treatment
More accurate pacemaker detection for advanced interpretation of paced rhythms
Enhanced barcode workflow, with orders and ADT download capability, work together to help improve efficiency across the enterprise
Connected ECG Workflow to help save time and avoid costly misdiagnoses
The MAC 5500 HD also meets the need for productivity across the enterprise, by empowering a wide range of users to precisely capture, analyze, and communicate ECG data. All to ensure the right data goes with the right patient to help reduce demographic and billing errors, and speed time to treatment.
Sophisticated tools. Easy to use.
The MAC 5500 HD enables clinicians to focus on what’s most important: their patients.